Drain and Sewer Cleaning Tools

100-101 Series Economy Drain Jet, Pressure range: 30-95 psig

102 Series Professional Drain Jet, Pressure range: 30-100 psig

103 Series Drain Jet Pro, Pressure range: use with Jetter pressures but never exceed pipeline capacity

107 Series Municipal Style Hydraulic Pipeline Flushers Sizes: 3" to 12"

109 Series Pipeline Cleaning Balls Sizes: 5.87" to 18.25"

Related Product Links

Plug Inflation Accessories

Product Use Guide

100-103 Series DrainJet™ Hydraulic Drain Flushers Sizes: 1 3/8" to 6"

Petersen Drain Flushers open clogged drains with powerful jet action and high flow rate. Easy to install even around bends and elbows. Much greater flow rate than rubber bulb-type flushers that require much of the pressure just to expand the rubber. DrainJet™ Hydraulic Drain Flusher puts all the water flow and pressure to work. The 100 to 102 Series have a 3/4" garden hose connection. The 103-Series have a NPT connection for use with your power Jetter and can double as a pipe plug (simply put a pipe plug in the outlet end, inflate up to 100 psi (60 psi for 6"), and use as a pipe plug).

Constructed of heavy duty specially treated industrial fabric.

DrainJet-Pro™ for the High
Pressure Jetter, 103-Series
DrainJet™ for the
Professional, 102-Series
Economy Drain Flushers: 100-Series Dr.FixIt & 101-Series Econo
     


1. Connect Flusher to water hose.


2. Insert Flusher into drain.


3. Turn on water. Bag expands, locks Flusher in pipe and flushes drain clear.

Click an Item Number below to order

Flushers, 103-Series, DrainJet-Pro™
Pipe Diameter Inlet Deflated Length Brand Name Shipping Item Number Unit Price

Each
Maximum Minimum Standard

Pack Ea
2/10 pk

lbs
in mm in mm in mm
1.50 38 1.375 34 3/8" NPT 8.75 222 DrainJet-Pro™ 1 1 103-001
2.50 63 1.50 38 3/8" NPT 9.25 235 DrainJet-Pro™ 1 1 103-002
3.00 76 2.50 63 3/8" NPT 13.00 330 DrainJet-Pro™ 1 2 103-003
4.00 101 3.00 76 3/8" NPT 14.75 375 DrainJet-Pro™ 1 2 103-004
6.00 152 4.00 101 3/8" NPT 20.25 514 DrainJet-Pro™ 1 3 103-006
Flushers, 102-Series, DrainJet™
1.50 38 1.375 34 3/4" Gdn. Hose 8.75 222 DrainJet™ 2 or 10 1 / 5 102-001
2.50 63 1.50 38 3/4" Gdn. Hose 9.25 235 DrainJet™ 2 or 10 1 / 5 102-002
3.00 76 2.50 63 3/4" Gdn. Hose 13.00 330 DrainJet™ 2 or 10 2 / 7 102-003
4.00 101 3.00 76 3/4" Gdn. Hose 14.75 375 DrainJet™ 2 or 10 2 / 8 102-004
6.00 152 4.00 101 3/4" Gdn. Hose 20.25 514 DrainJet™ 2 3 102-006
Flushers, 100-Series Dr.FixIt / 101-Series Econo
2.00 51 1.50 38 3/4" Gdn. Hose 8.00 203 Econo 2 or 10 1 / 5 101-002
4.00 101 1.625 41 3/4" Gdn. Hose 9.00 229 Dr.FixIt 2 1 100-004
6.00 152 3.00 76 3/4" Gdn. Hose 13.00 330 Dr.FixIt 2 2 100-006

Custom configurations also available

Products covered by one or more of the following patents: 4,565,222; 5,353,842; 5,901,752; 6,446,669; 6,568,429; 6,899,138 and other applications pending.


107 Series Municipal Style Hydraulic Pipeline Flushers Sizes: 3" to 12"

  • Manufactured with heavy industrial treated woven canvas.
  • Multi size configuration allows use in smaller than the rated size. Leak back may increase for smaller size pipes.
  • Light Weight Allows one person insertion for most sizes and applications.
  • Flexibility allows easy navigation through bends and small openings.
  • Under Water Placement is easier due to the small deflated size and minimal internal air
  • May be used as a plug with water or air by capping the outlet.
  • Generally in stock up to 12" diameter with larger and smaller sizes available in just a few days.
  • Custom Configurations available for most size, temperature, chemical, and pressure requirements.

Clear Sand & Debris
  1. Insert Flusher above debris with outlet pointed up stream
  2. Turn on water full force allowing water head build up
  3. Turn off water and remove Flusher; the released head of water clears pipeline
Clear Obstructed Sewer
  1. Insert Flusher above debris with outlet pointed down stream
  2. Turn on water full force allowing water to expand Flusher
  3. Water flow and pressure builds between Flusher and blockage clearing sewer

Click an Item Number below to order

Pipe Diameter Maximum*
Flushing
Pressure
Inlet
Coupling

Outlet
Connection

in npt

Deflated Length Shpg
Wt
lbs
Item
Number**

Unit
Price

Each

Maximum Minimum
in mm in mm in mm
4 102 3 76 100 psig 1 1/2" npsm 1 M 17 431 4 107-004-1
4 102 3.5 89 100 psig 2 1/2" nh 1 1/2 M 17 431 7 107-004-3
6 152 4.0 102 100 psig 1 1/2" npsm 1 M 22 558 5 107-006-1
6 152 5.0 127 100 psig 2 1/2" nh 1 1/2 M 22 558 8 107-006-3
8 203 4.0 102 100 psig 1 1/2" npsm 1 M 25 635 6 107-008-1
8 203 5.0 127 100 psig 2 1/2" nh 1 1/2 M 25 635 9 107-008-3
10 254 4.0 102 100 psig 2" npsm 1 1/4 M 37 939 8 107-010-2
10 254 5.0 127 100 psig 2 1/2" nh 1 1/2 M 37 939 13 107-010-3
12 305 4.0 102 100 psig 2" npsm 1 1/4 M 42 1067 13 107-012-2
12 305 5.0 127 100 psig 2 1/2" nh 2 M 42 1067 14 107-012-3

Custom configurations also available

*Warning: When used as an inflatable plug, inflate only to 25% of the flushing pressure! Maximum head pressures that a pipe plug may restrain can only be estimated. Slippage is influenced by many factors including fluid in the pipe, coefficient of pipeline friction, pressure required to inflate the plug, and accuracy of pressure gauges. Generally, a Multi-Flex™ Inflatable Plug inserted fully into pipeline will begin slipping between 50% and 80% of the inflation pressure if it has an inflated pipe contact length of 1 ½ to 2 times the diameter, but even a head pressure of 50% of the inflation pressure may cause slippage with some liquids. The inflation pressure is also subject to temperature change and debris or protrusions in the pipeline that could rupture the plug. The inflation pressure should be monitored and plugs anchored and/or mechanically blocked when slippage could cause property damage or injury. NEVER use a test pressure greater than the capacity of the weakest pipe or component in the system. NEVER use an inflatable plug when its failure could cause injury or catastrophic damage.

Products covered by one or more of the following patents: 4,565,222; 5,353,842; 5,901,752; 6,446,669; 6,568,429; 6,899,138 and other applications pending.


109 Series Pipeline Cleaning Balls Sizes: 5.87" to 18.25"

cleaning balls

Manhole Winch manhole winch

Features:

  • Drags plugs in leak location testing
  • Feeds Pipeline Cleaning Ball down line for sewer cleaning
  • Normal pull strength up to 550 pounds
  • 3/32" diameter steel cable

Other Accessories

Click an Item Number below to order

Description
Shpg
Wt
lbs
Item
Number
Unit
Price
Each
Manhole Winch 30 938-7826
Nominal Size Range of Use Head Pressure (Feet of Head) Deflated Length Deflated Diameter Inflation Valve Thread Size Eye Bolt Shpg
Wt
lbs
Item Number Unit Price Each

6" - 10"

(150 - 250 mm)

5.87"

(149 mm)

10.25"

(260 mm)

5

(1.5 M)

8"

(203 mm)

5.62"

(142 mm)

1/4" (1) 3/8" (2) 4 109-010

10" - 14"

(250 - 350 mm)

8.75"

(222 mm)

14.25"

(362 mm)

5

(1.5 M)

12.25"

(311 mm)

8.5"

(216 mm)

1/4" (1) 3/8" (2) 10 109-014

15" - 18"

(375 - 450 mm)

11"

(279 mm)

18.25"

(464 mm)

5

(1.5 M)

14.75"

(375 mm)

10.75"

(273 mm)

1/4" (1) 3/8" (2) 16 109-018
 

**Inflatable Plug Warning: Maximum head pressures that a pipe plug may restrain can only be estimated. Slippage is influenced by many factors including fluid in the pipe, coefficient of pipeline friction, pressure required to inflate the plug, and accuracy of pressure gauges. Generally, a Multi-Flex™ Inflatable Plug inserted fully into pipeline will begin slipping between 50% and 80% of the inflation pressure if it has an inflated pipe contact length of 1 ½ to 2 times the diameter, but even a head pressure of 50% of the inflation pressure may cause slippage with some liquids. The inflation pressure is also subject to temperature change and debris or protrusions in the pipeline that could rupture the plug. The inflation pressure should be monitored and plugs anchored and/or mechanically blocked when slippage could cause property damage or injury. NEVER use a test pressure greater than the capacity of the weakest pipe or component in the system. NEVER use an inflatable plug when its failure could cause injury or catastrophic damage.