147 Series Bolt Type High Pressure Test Plugs Sizes: 2.27" to 4.25"
Click an Item Number below to order
| High Pressure Test Plugs 2.27" to 4.25" ID Sizes |
| Nominal Pipe | By-Pass
Connection
NPT | Pipe I.D. Size Range | *Maximum Test | Std. Seal
Mat'l
(4) | Shaft Qty | Installation Depth | Overall Length | Shpg
Wt
lbs | Item
Number | Unit Price
Each |
| Maximum | Minimum | Pressure (2)(3) |
| Size | Sched | in | mm | in | mm | psig | bar | in | mm | in | mm |
| 2.50 | 80/XS | 3/8M | 2.45 | 62.2 | 2.27 | 57.7 | 5,900 | 410 | U | 1 | 2.88 | 73.0 | 7 | 177.8 | 4 | 147-0025-P80 | |
| 3.00 | XXS | 3/8M | 2.45 | 62.2 | 2.27 | 57.7 | 11,100 | 770 | U | 1 | 2.88 | 73.0 | 7 | 177.8 | 4 | 147-0030-PXXS | |
| 2.50 | 40 / STD | 1/2M | 2.54 | 64.5 | 2.44 | 62.0 | 4,200 | 290 | U | 1 | 3 | 76.2 | 9 | 227 | 6 | 147-0025-P40 | |
| 2.50 | 10 | 1/2M | 2.74 | 69.6 | 2.60 | 66.0 | 2,400 | 170 | U | 1 | 3.31 | 84.1 | 9 | 227 | 7 | 147-0025-P10 | |
| 3.00 | 160 | 1/2M | 2.74 | 69.6 | 2.60 | 66.0 | 7,800 | 540 | U | 1 | 3.31 | 84.1 | 9 | 227 | 7 | 147-0030-P160 | |
| 2.50 | 5 | 1/2M | 2.78 | 70.6 | 2.68 | 68.1 | 1,600 | 110 | U | 1 | 3 | 76.2 | 9 | 227 | 7 | 147-0025-P5 | |
| 3.50 | XXS | 1/2M | 2.89 | 73.4 | 2.70 | 68.6 | 10,200 | 700 | U | 1 | 3.50 | 88.9 | 9 | 227 | 8 | 147-0035-PXXS | |
| 3.00 | 80/XS | 1/2M | 2.98 | 75.7 | 2.87 | 72.9 | 5,200 | 360 | U | 1 | 3.19 | 81.0 | 9 | 227 | 8 | 147-0030-P80 | |
| 3.00 | 40 / STD | 1/2M | 3.14 | 79.8 | 3.04 | 77.2 | 3,700 | 260 | U | 1 | 3.19 | 81.0 | 9 | 227 | 8 | 147-0030-P40 | |
| 4.00 | XXS | 1/2M | 3.32 | 84.3 | 3.12 | 79.2 | 9,500 | 660 | U | 1 | 3.81 | 96.8 | 9 | 227 | 9 | 147-0040-PXXS | |
| 3.00 | 10 | 1/2M | 3.34 | 84.8 | 3.23 | 82.0 | 2,000 | 140 | U | 1 | 3.19 | 81.0 | 9 | 227 | 9 | 147-0030-P10 | |
| 3.00 | 5 | 1/2M | 3.41 | 86.6 | 3.30 | 83.8 | 1,400 | 100 | U | 1 | 3.19 | 81.0 | 9 | 227 | 9 | 147-0030-P5 | |
| 3.50 | 80/XS | 1/2M | 3.44 | 87.4 | 3.33 | 84.6 | 4,800 | 330 | U | 1 | 3.31 | 84.1 | 9 | 227 | 9 | 147-0035-P80 | |
| 4.00 | 160 | 1/2M | 3.57 | 90.7 | 3.41 | 86.6 | 7,400 | 510 | U | 1 | 3.69 | 93.7 | 9 | 227 | 10 | 147-0040-P160 | |
| 3.50 | 40 / STD | 1/2M | 3.63 | 92.2 | 3.52 | 89.4 | 3,300 | 230 | U | 1 | 3.31 | 84.1 | 9 | 227 | 10 | 147-0035-P40 | |
| 4.00 | 120 | 1/2M | 3.74 | 95.0 | 3.60 | 91.4 | 6,000 | 410 | U | 1 | 3.63 | 92.1 | 9 | 227 | 11 | 147-0040-P120 | |
| 3.50 | 10 | 1/2M | 3.84 | 97.5 | 3.73 | 94.7 | 1,700 | 120 | U | 1 | 3.31 | 84.1 | 9 | 227 | 11 | 147-0035-P10 | |
| 3.50 | 5 | 1/2M | 3.91 | 99.3 | 3.80 | 96.5 | 1,200 | 80 | U | 1 | 3.56 | 90.5 | 9 | 227 | 12 | 147-0035-P5 | |
| 4.00 | 80/XS | 1/2M | 3.91 | 99.3 | 3.80 | 96.5 | 4,500 | 310 | U | 1 | 3.56 | 90.5 | 9 | 227 | 12 | 147-0040-P80 | |
| 4.00 | 40 / STD | 1/2M | 4.11 | 104.4 | 4.00 | 101.6 | 3,100 | 210 | U | 1 | 3.63 | 92.1 | 9 | 227 | 12 | 147-0040-P40 | |
| 5.00 | XXS | 1/2M | 4.25 | 108.0 | 4.03 | 102.4 | 8,500 | 590 | U | 1 | 4.31 | 109.5 | 9 | 227 | 14 | 147-0050-PXXS | |
| Other sizes and seal material available IMPORTANT: - M = Male NPT, F = Female NPT
- NEVER use a test pressure greater than the weakest component in the
system can handle. Test Pressure specified in table is equivalent to
80% of the pressure
that will yield ASTM A106 Grade B pipe. The test pressure for higher
and lower strength pipes will differ proportionally. The maximum test
pressure for higher
strength pipe must never exceed the highest test pressure listed for
that pipe O.D.
- Sizes that do not have a test pressure listed differ from standard
pipe sizes. These plug sizes are normally used to test tubing. For use
of these
plug sizes in tubing with a minimum yield strength of 35ksi, the maximum
test pressure is estimated by the test pressure listed for the equivalent
or next
larger pipe O.D. with the equivalent or next thinner wall thickness.
The test pressure for higher and lower strength tubes will differ proportionally.
The
maximum test pressure for higher strength tubes must never exceed the
highest test pressure listed for the equivalent or next larger pipe size.
NEVER use
a test pressure greater than the weakest component in the system can
safely handle.
- Standard Seal Material: U = Urethane, N = Neoprene
*Mechanical Plug Warning: Maximum head pressures that a pipe plug may hold back can only be estimated. Pressures are influenced by many factors including fluid and debris in the pipeline, type and condition of pipe, tightness of plug seal, and temperature. Plugs should always be inserted fully into pipeline and should be mechanically blocked when slippage could cause property damage or injury. NEVER use a test pressure greater than the capacity of the weakest pipe or component in the system. NEVER use a mechanical plug when its failure could cause injury. Specifications subject to change without notice Price subject to change without notice Petersen Terms & Conditions Apply |