Petersen® Hydraulic Municipal Sewer Flusher, 107 Series
Flush Clogged Sewers and Clear Debris & Sand
Key Benefits
- Connections for Fire Hydrant Hose
- Flush Clogged Sewers and Clear Debris and Sand
- Flexibility allows easy navigation through bends and small openings
- Under Water Placement is easier due to the small, deflated size
- Light Weight allows one person insertion for most sizes and applications
- Manufactured with heavy industrial treated canvas
- Multi size configuration allows use in smaller than the rated size
- Leak back may increase for smaller size pipes
- Use as a plug with water or air, by capping the outlet

| Image | Dia. Max | Dia. Min | Press., Max. Flushing, PSI | Connection, Inlet | Outlet Connection | Length Deflated | Shipping Wt. | Item Number | Price | Qty | Action |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
14" (355.6mm) | 5" (127mm) | 100 psi (6.89 bar) | 2.5" NH | 2" MNPT | 45" (1143mm) | 14 Lb (6.35 Kg) | 107-014-3 |
$977.00
|
||
|
12" (304.8mm) | 5" (127mm) | 100 psi (6.89 bar) | 2" MNPT TO 2.5" Female NH | 2" MNPT | 42" (1066.8mm) | 21 Lb (9.53 Kg) | 107-012-3 |
$836.00
|
||
|
12" (304.8mm) | 4" (101.6mm) | 100 psi (6.89 bar) | 2" NPSM Female Hose Coupling | 1-1/4" MNPT | 42" (1066.8mm) | 13 Lb (5.90 Kg) | 107-012-2 |
$745.00
|
||
|
10" (254mm) | 5" (127mm) | 100 psi (6.89 bar) | 2" MNPT TO 2.5" Female NH | 1-1/2" MNPT | 37" (939.8mm) | 13 Lb (5.90 Kg) | 107-010-3 |
$745.00
|
||
|
10" (254mm) | 4" (101.6mm) | 100 psi (6.89 bar) | 2" NPSM Female Hose Coupling | 1-1/4" MNPT | 37" (939.8mm) | 8 Lb (3.63 Kg) | 107-010-2 |
$652.00
|
||
|
8" (203.2mm) | 5" (127mm) | 100 psi (6.89 bar) | 2" MNPT TO 2.5" Female NH | 1-1/2" MNPT | 25" (635mm) | 9 Lb (4.08 Kg) | 107-008-3 |
$587.00
|
||
|
8" (203.2mm) | 4.5" (114.3mm) | 100 psi (6.89 bar) | 2" NPSM Female Hose Coupling | 1" MNPT | 25" (635mm) | 7 Lb (3.18 Kg) | 107-008-2 |
$461.00
|
||
|
8" (203.2mm) | 4" (101.6mm) | 100 psi (6.89 bar) | 1.5" NPSM Female Hose Coupling | 1" MNPT | 25" (635mm) | 6 Lb (2.72 Kg) | 107-008-1 |
$496.00
|
||
|
6" (152.4mm) | 5" (127mm) | 100 psi (6.89 bar) | 2" MNPT TO 2.5" Female NH | 1-1/2" MNPT | 22" (558.8mm) | 8 Lb (3.63 Kg) | 107-006-3 |
$496.00
|
||
|
6" (152.4mm) | 4.5" (114.3mm) | 100 psi (6.89 bar) | 2" NPSM Female Hose Coupling | 1" MNPT | 22" (558.8mm) | 6 Lb (2.72 Kg) | 107-006-2 |
$382.00
|
||
|
6" (152.4mm) | 4" (101.6mm) | 100 psi (6.89 bar) | 1.5" NPSM Female Hose Coupling | 1" MNPT | 22" (558.8mm) | 5 Lb (2.27 Kg) | 107-006-1 |
$403.00
|
||
|
4" (101.6mm) | 3.5" (88.9mm) | 100 psi (6.89 bar) | 2" MNPT TO 2.5" Female NH | 1-1/2" MNPT | 17" (431 mm) | 7 Lb (3.18 Kg) | 107-004-3 |
$451.00
|
||
|
4" (101.6mm) | 3" (76.2mm) | 100 psi (6.89 bar) | 2" NPSM Female Hose Coupling | 1" MNPT | 17" (431.8mm) | 4 Lb (1.81 Kg) | 107-004-2 |
$349.00
|
||
|
4" (101.6mm) | 3" (76.2mm) | 100 psi (6.89 bar) | 1.5" NPSM Female Hose Coupling | 1" MNPT | 17" (431.8mm) | 4 Lb (1.81 Kg) | 107-004-1 |
$373.00
|
Petersen municipal sewer flushers are durable instruments to clear debris from stormwater and sewer pipes. These sewer flushers connect to a fire hydrant and send high-pressure water through clogged lines. They are lightweight and flexible, making them easier to insert and use in tight or submerged spaces. Each sewer flusher is ideal for public works crews and utility teams, as it keeps sewer lines clean and operational.
Features of Municipal Sewer Flushing Tools
Sewer flushing tools are designed for durability, ease of use, and performance in municipal and industrial environments. The key features include:
- Industrial-grade treated canvas for durability and long service life.
- Flexible design fits a variety of pipe sizes for improved adaptability.
- Lightweight structure allows for single-operator handling.
- Compact deflated size allows for use in submerged or confined situations.
- Dual-purpose—can flush waste or serve as a plug by capping the outlet.
- Custom options are available to meet specific size, pressure, chemical, and temperature requirements.
These features make each municipal sewer flushers a reliable option for cleaning stormwater and sanitary sewage lines.
How to Use a Municipal Sewer Flusher
To begin, attach the municipal sewer flusher to a fire hydrant or comparable hose with the appropriate coupler. Once connected, place the deflated flusher in the pipe. Its flexible structure allows it to navigate curves and accommodate a variety of pipe sizes. After positioning the flusher, turn on the water to inflate it and start flushing. The high-pressure water flow will push dirt, sand, and other blockages out of the pipe.
This procedure has been found to be effective for flushing clogged sewers in both stormwater and sanitary systems. For detailed steps and safety guidelines, refer to the instruction manual.
Choosing the Right Sewer Flusher Size
Choosing a sewer flusher depends on the diameter of the pipe, the type of blockage, and the system's pressure requirements. Each sewer flusher is designed to work within a specified pipe diameter range, so select a type that matches or slightly undersizes the pipe to ensure proper sealing and flushing.
Pressure capacity should also be consistent with the water source—most versions are compatible with standard fire hydrant connections and can take up to 100 PSI. Always check the inlet and output connection types to guarantee a proper fit with your hydrant hose or flushing equipment. Using the optimum size and pressure capacity maximizes cleaning efficiency while reducing equipment wear.
Custom Sewer Flusher Configurations Available
Petersen Products provides a complete line of custom sewer flusher options to meet specific needs in municipal, industrial, and utility applications. Custom configurations are available for non-standard pipe sizes, high temperatures, unique chemical conditions, and various pressure capacities. These solutions ensure consistent performance even under the most difficult conditions.
Whether you require specific input or outlet connections, additional hose compatibility, or material enhancements for chemical resistance, Petersen Products can design a solution to meet your system. Custom sewer flushers are perfect for agencies and contractors who face unusual flushing issues and require precision-engineered equipment to complete the task properly.
Applications for Municipal Sewer Flushers
A municipal sewer cleaning tool is crucial for keeping sewer and stormwater systems clean and functional. Common applications include:
- Sediment and Debris Removal - Removes accumulated garbage, silt, and clogs from sewer and stormwater systems.
- Sand Buildup Elimination - Removes heavy sand deposits that frequently accumulate in low-slope or slow-flowing pipelines.
- Stormwater Flushing - Maintains clean and effective drainage in stormwater systems to prevent backups.
- Sanitary Sewer Cleaning - Flushes clogged sanitary lines, restoring proper flow in home and municipal systems.
- Pre-Inspection Preparations - Cleans pipes prior to CCTV inspections or evaluations to provide accurate, unobstructed results.
These tools are essential for routine sewer line repair and the proper operation of municipal water infrastructure.
Order Municipal Sewer Flushers Online
Browse our inventory of municipal sewer flushers to find the best fit for your needs. Click on any item number to view complete product information, specifications, and pricing
For questions or custom orders, contact Petersen Products at 262-692-3100 or sales@petersenproducts.com. Our team is ready to help you in selecting the appropriate sewer flushing tool for your specific requirements.




















Annular Seals, Inflatable and Mechanical
Custom Manufacturing Solutions
Drain Flushers & Sewer Cleaning Tools
Duct Balloons, Grout Bags, Bladders
Hot Tap Machines & Equipment
Inflation Accessories & Pipeline Fittings
Lifting Bags, Inflatable
Packers Carriers, Relining Inflatable
PeteStop® Inflatable Line Stop Pipe Plugs to block Pressurized Pipelines
PeteStop® Line Stop Systems, Components & Tools
Pipe Plugs - Inflatable All Types
Pipe Plugs - Mechanical All Types
Pipe Plugs, Inflatable Rubber Molded
Pipe Plugs, Mechanical High Pressure
Pipe Plugs, Mechanical Low Pressure
Pipe Plugs, Multi-Flex® Chemical Resistant
Pipeline Test Equipment
Temperature and Pressure Test Plugs
Tools for Contractors